IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V multiconductor Type P control cables

Conductor:

Stranded copper conductor tin or alloy coated where necessary for the application , conductor per ASTM or IEC

60228.

Separator tape: optional

Insulation:

Cross-linked polyolefin(XLPO)according to IEEE 1580 2010 Type P,Type X, E, T, T/N, S, P, LSX and LSE as option.

Shielding: optional

Jacket:

Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or TPO

jacket as option (optional for Type P with HD thicknesses).

Armor: optional and shall be nonmagnetic

Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P

or TPO sheath as option (optional except for tinned copper braid armoured cables).

Optional:

For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.10—Typical dimensions and weights; multiconductor control 600/1000 V; Type P cables


Number of conductors
Conductor
AWG size

Unarmored

Armored

Armored and sheathed

Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft)

Nom. dia. (in)

Approx. weight (lb/1000 ft)
4 16 0.423 99 0.473 154

0.604

227
5 16 0.458 110 0.508 171

0.639

264
7 16 0.494 155 0.544 265

0.675

300
8 16 0.531 164 0.581 255

0.712

330
10 16 0.615 206 0.665 366

0.796

445
16 16 0.7 299 0.75 465

0.923

602
20 16 0.773 360 0.823 560

0.996

724
24 16 0.899 462 0.949 718

1.122

809
37 16 1.02 658 1.07 819

1.243

989
44 16 1.096 807 1.146 980

1.319

1175
60 16 1.262 1053 1.312 1256

1.485

1496
91 16 1.504 1595 1.554 1896

1.79

2181
4 14 0.459 128 0.509 213

0.64

275
5 14 0.498 149 0.548 234

0.679

301
6 14 0.539 182 0.589 264

0.72

335
7 14 0.539 205 0.589 297

0.72

377
10 14 0.675 280 0.725 406

0.898

515
12 14 0.696 307 0.746 428

0.919

558
14 14 0.731 415 0.781 540

1.117

876
24 14 0.989 615 1.039 892

1.212

1132
30 14 1.045 780 1.095 965

1.268

1180
37 14 1.125 876 1.175 1135

1.348

1405
44 14 1.21 1087 1.26 1260

1.433

1477
91 14 1.669 2200 1.719 2465

1.955

2855
4 12 0.505 168 0.555 256

0.686

323
5 12 0.55 196 0.6 266

0.731

334
6 12 0.596 280 0.646 405

0.777

500
10 12 0.751 369 0.801 500

0.974

629
20 12 0.995 701 1.045 890

1.218

1055
24 12 1.103 861 1.153 1167

1.326

1468
37 12 1.258 1262 1.308 1467

1.481

1677

NOTE—These values are for reference purposes only and should not be construed as requirements. Weights of armored constructions are based on bronze braid armor. It is recommended that the user/specifier contact the manufacturer for manufacturer specific values.